Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.13.10.(2)
OS2OP2OH1OS1
ObjectiveOS1 Fire Safety
Attribution
[F20,F22-OS1.2] Applies to assemblies required to provide fire resistance.
Application
Application 1: 
Minimum depth of lumber ceiling joists supporting struts or dwarf walls that in turn support roof rafters, where the roof slope is 1 in 4 or less, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate strength, which could lead to an inability to resist bending stress imposed by struts or dwarf walls in addition to other expected gravity and lateral loads, which could lead to:
  • the failure of the roof or of the ceiling joists, or
  • the excessive deflection of the roof, which could lead to the opening of joints.
Where assemblies are required to provide fire resistance, this is to limit the probability of compromised fire resistance of the assembly, which could lead to harm to persons.
Intent 2: 
To limit the application of Sentence (1) for constructions where support for increased roof loads has to be provided.