Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.23.13.11.(3) | Application | Intent |
OS2 | OP2 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Bracing for compression web members longer than 1.83
m, in roof trusses that have not been designed in accordance with Part
4, in wood-frame constructions to which Section 9.23. applies
[see Sentence 9.23.1.1.(1) for application of Section 9.23.].
|
Top of Page | |
Intent | Intent 1: To limit the probability of an inability to resist expected
gravity or lateral loads, which could lead to buckling failure of compression
members, which could lead to the structural collapse of roofs, which could
lead to harm to persons. |
Top of Page |