Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.23.16.4.(2) | Application | Intent |
OS2 | OP2 | OH1 | OS1 | OS3 | OH4 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Staggered end joints for diagonally-applied lumber
wall sheathing used to provide bracing, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application
of Section 9.23.]. |
Top of Page | |
Intent | Intent 1: To limit the probability of discontinuity in the sheathing,
which could lead to an inability to resist expected lateral or gravity loads,
which could lead to the excessive movement, deformation or failure of exterior
walls. Where assemblies are required to provide fire
resistance, this is to limit the probability of compromised fire resistance
of the assembly, which could lead to harm to persons.
|
Top of Page |