Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.23.16.5.(1)
OS2OP2OH1OH4OS3
ObjectiveOH4 Vibration and Deflection Limitation
Attribution
[F80,F81-OH4] Applies to floors and elements that support floors.
Application
Application 1: 
Minimum size of gaps between wood-based panels used in wall sheathing, in wood-frame constructions to which Section 9.23. applies [see Sentence 9.23.1.1.(1) for application of Section 9.23.].
Top of Page
Intent
Intent 1: 
To limit the probability of an inability to accommodate dimensional changes due to variations in moisture content, which could lead to jamming of sheet edges, which could lead to buckling of cladding.
For exterior floors or environmental separators supporting such a floor, this is to limit the probability of the excessive deformation, displacement or failure of required environmental separation elements, which could lead to deterioration, which could lead to compromised structural integrity, which could lead to excessive movement, vibration or deflection, which could lead to negative effects on the psychological well-being of persons.
Top of Page