Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.24.2.4.(4) | Application | Intent |
OS1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Intermediate support for framing above door openings
in non-loadbearing, steel stud fire
separations required to have a fire-resistance
rating, in buildings to which Part 9 applies
[see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
|
Top of Page | |
Intent | Intent 1: To limit the probability of inadequate top support for the
frames of rated doors, which could lead to an inadequate resistance to forces
exerted by the warping of rated doors under fire loads, which could lead to
the opening of gaps between such doors and their frames. This
is to limit the probability of compromised fire resistance of the assembly,
which could lead to harm to persons.
|
Top of Page |