Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.24.3.2.(1) | Application | Intent |
OS1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Minimum clearance between the top of steel studs and
the top of runners in non-loadbearing exterior
and interior walls required to have a fire-resistance
rating, in buildings to which Part 9 applies
[see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
|
Top of Page | |
Intent | Intent 1: To limit the probability of insufficient clearance to accommodate
the linear expansion of steel studs during a fire, which could lead to the
buckling of studs, which could lead to the premature failure of fire-rated
assemblies, which could lead to harm to persons. |