Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.24.3.2.(3) | Application | Intent |
OS1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Framing above doors installed in steel door frames
in non-loadbearing exterior and interior fire separations required to have a fire-resistance
rating, in buildings to which Part 9 applies
[see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
|
Top of Page | |
Intent | Intent 1: To limit the probability that framing will be of inadequate
stiffness to resist forces exerted by the twisting of door frames on exposure
to heat from a fire, which could lead to the premature failure of fire-rated
assemblies, which could lead to harm to persons. |
Top of Page |