Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.24.3.6.(2) | Application | Intent |
OS1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Attachment of steel studs to runners in non-loadbearing exterior and interior walls of buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9]. |
Top of Page | |
Intent | Intent 1: To limit the probability that attaching steel studs to both
the top and bottom runners will hinder the linear expansion of steel studs
during a fire, which could lead to the buckling of studs, which could lead
to the premature failure of fire-rated assemblies, which could lead to harm
to persons. |