Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.25.2.3.(3)
OH1OS2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Installation of thermal insulation in walls, ceilings, roofs and floors separating heated space from unheated space, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of convective loops of air on the cold face and air on the warm face of thermal insulation, which could lead to the cooling of interior surfaces, which could lead to excessively low temperatures of interior surfaces or within assemblies.
This is to limit the probability of condensation, which could lead to deterioration, which could lead to compromised structural integrity of assemblies acting as or protected by environmental separators, which could lead to harm to persons.