Warning This information has been archived because it is outdated and no longer relevant.

Archived Content

Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.25.2.3.(5)
OH1OS2
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Location of insulation around concrete slabs-on-ground, where exterior walls are not supported by footings extending below frost level, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability that insufficient heat will reach the soil around foundations, which could lead to the freezing of soil, which could lead to frost-related soil movement, which could lead to cracking of footings, slabs-on-ground or building envelope assemblies supported by footings or slabs-on-ground.
This is to limit the probability of:
  • condensation,
  • precipitation ingress, or
  • the ingress of moisture from the ground.
This is to limit the probability of:
  • an inadequate control of the temperature of interior spaces or relative humidity,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of assemblies acting as or protected by environmental separators.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.