Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.25.3.2.(2)
OH1OS2OS1OS3
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Polyethylene sheets used to provide airtightness in required air barrier systems, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability that the performance of polyethylene sheets will fall significantly below expectations, which could lead to an inability to resist loads induced by air pressure differences, which could lead to the sheets rupturing or tearing at fasteners, or becoming prematurely brittle, which could lead to the failure of the membrane.
This is to limit the probability of a loss of airtightness, which could lead to:
  • excessive heat loss or gain due to air mass transfer,
  • excessive air infiltration and exfiltration,
  • excessive airborne vapour transfer from interior above ground and exterior below ground, or
  • precipitation ingress due to air pressure differences.
This is to limit the probability of condensation or the accumulation of water, which could lead to deterioration, which could lead to compromised structural integrity of assemblies acting as or protected by environmental separators, which could lead to harm to persons.
Top of Page