Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.26.4.8.(1)
OH1OS2OS1OP1OS3
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Installation of saddles at junctions, more than 750 mm wide, of sloping roofs with the upper side of chimneys, on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Sentence 9.26.4.8.(5), which applies to shingle roofs where the intersection between the chimney and roof is protected by sheet metal flashing that meets certain criteria.
Top of Page
Intent
Intent 1: 
To limit the probability that the flow of water down a roof's surface will be interrupted by a wide chimney, which could lead to a temporary increase in water depth beyond the depth protected by roofing or by the vertical leg of flashing at the chimney, which could lead to precipitation or meltwater ingress, which could lead to damage to masonry or to chimney liners from freeze-thaw stresses, which could lead to the escape of heat or flames, which could lead to the ignition of combustible building components, which could lead to harm to persons [see analysis for Sentence 9.21.4.6.(1)].