Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.26.5.1.(1)
OH1OS2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Eave protection for shingle, shake or tile roofs, on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Sentence 9.26.5.1.(2), which applies to roofs where there is little probability of ice dam formation.
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate protection of the roof area where water is being retained near the eaves by ice dams or where heat transferred through the ceiling below causes snow to melt and ice dams to form.
This is to limit the probability of precipitation or meltwater ingress, which could lead to deterioration, which could lead to the structural failure of roofs or assemblies protected by roofs, which could lead to harm to persons.