Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.26.6.2.(1) | Application | Intent |
OH1 | OS2 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Orientation and overlapping of underlay used beneath
shingles, on roofs of buildings to which Part 9
applies [see Sentence 1.3.3.3.(1) of Division A for application of Part
9]. |
Top of Page | |
Intent | Intent 1: To limit the probability of the retention of water that
has penetrated roofing or that has condensed on the underside of underlay,
which could lead to long-term wetting of sheathing, which could lead to deterioration,
which could lead to the structural failure of roofs or assemblies protected
by roofs, which could lead to harm to persons. |