This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.26.6.2.(2) | Application | Intent |
OH1 | OS2 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Fastening of underlay used beneath shingles, on roofs
of buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]. |
Top of Page | |
Intent | Intent 1: To limit the probability of the retention of water that
has penetrated roofing or that has condensed on the underside of underlay,
which could lead to long-term wetting of sheathing, which could lead to deterioration,
which could lead to further:
This is to limit the probability of:
This is to limit the probability of:
This is to limit the probability of harm to persons.
|
Top of Page |