Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.26.7.2.(2) | Application | Intent |
OH1 | OS2 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Materials for starter strips for asphalt shingles,
on roofs of buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions:
except as stated in Sentence 9.26.7.2.(3), which applies where
eave protection of not less than Type M mineral-surfaced roll roofing is provided.
Application 2: This also applies to asphalt shingles installed as
cladding, as stated in Sentence 9.27.1.1.(4). Application 3: This also applies to starter strips for asphalt shingles
on roofs having a slope of less than 1 in 3, as stated in Sentence 9.26.8.2.(1).
|
Top of Page | |
Intent | Intent 1: To limit the probability of cutouts that coincide with those
of the top layer of shingles, which could lead to less than the required 2
thicknesses of shingle over the entire roof, which could lead to insufficient
protection of roof decking or sheathing from moisture absorption, ultraviolet
radiation, and freeze-thaw cycling, which could lead to premature failure,
which could lead to:
This is to limit the probability of:
This is to limit the probability of:
This is to limit the probability of harm to persons.
|