Warning This information has been archived because it is outdated and no longer relevant.

Archived Content

Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.26.7.4.(2)
OH1OS2
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Minimum number of staples for fastening asphalt shingles, on roofs of buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where staples with an 11-mm crown are used.
Application 2: 
This also applies to asphalt shingles installed as cladding, as stated in Sentence 9.27.1.1.(4).
Application 3: 
This also applies to the fastening of asphalt shingles on roofs with slopes of less than 1 in 3, as stated in Sentence 9.26.8.7.(1).
Exceptions: 
except as stated in Sentence 9.26.7.4.(3), which applies to shingles that are less than 1 m wide.
Top of Page
Intent
Intent 1: 
To limit the probability of:
  • an inadequate bearing area between the staple's crown and the shingle's surface, which could lead to excessive stress on the staple/shingle interface, which could lead to pull-through, or
  • an inadequate resistance to withdrawal from the substrate.
This is to limit the probability of the displacement of shingles, which could lead to:
  • water penetrating directly to roof decking or sheathing, or
  • compromised thermal performance of components intended to provide resistance to heat transfer.
This is to limit the probability of:
  • an inadequate control of relative humidity, temperatures of interior spaces or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of roofs or walls or of assemblies protected by roofs or walls.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.
Intent 2: 
To supersede the requirement for 4 fasteners stated in Sentences 9.26.2.3.(2) and 9.26.7.4.(1), and increase the number of fasteners to 6 for constructions where relatively narrow staples are used.
Top of Page