This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.27.4.1.(1) | Application | Intent |
OH1 | OS2 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Caulking at points of potential precipitation entry
into wall assemblies that are not otherwise protected by features such as
roof overhangs, flashing or substantial lap joints, as provided elsewhere
in this Section, on buildings to which Part 9 applies[see Sentence 1.3.3.3.(1) of Division A for application of Part 9]. |
Top of Page | |
Intent | Intent 1: To limit the probability of unsealed joints at points not
protected by roof overhangs or flashing, which could lead to:
This is to limit the probability of:
This is to limit the probability of:
This is to limit the probability of harm to persons.
|
Top of Page |