Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.27.4.2.(2)
OH1OS2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Caulking [required by Article 9.27.4.1.], for buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
  • between masonry, siding or stucco and adjacent doors and window frames or trim, including sills, unless such locations are otherwise completely protected from the entry of rain,
  • at vertical joints between different cladding materials, unless such joints are suitably lapped or flashed to prevent the entry of rain, and
  • as otherwise required to prevent the entry of water into the structure.
Top of Page
Intent
Intent 1: 
To limit the probability that the performance of caulking materials will fall significantly below expectations, which could lead to the premature failure of caulked joints, which could lead to precipitation or meltwater ingress, which could lead to deterioration, which could lead to the structural failure of exterior walls or elements protected by exterior walls, which could lead to harm to persons.