Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.27.10.1.(1)
OH1OS2
ObjectiveOS2 Structural Safety
Attribution
[F20-OS2.1,OS2.3,OS2.4] [F22-OS2.3,OS2.4,OS2.5] Applies where panel-type cladding is installed to provide the required bracing.
Application
Application 1: 
Factory-finished hardboard cladding, on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability that the performance of factory-finished hardboard cladding will fall significantly below expectations, which could lead to:
  • the premature failure of hardboard cladding, or
  • where panel-type siding is installed as bracing to satisfy Subclause 9.23.10.2.(2)(b)(i), an inability to resist lateral loads, which could lead to racking of exterior walls.
This is to limit the probability of the displacement of cladding, trim and flashing, opening of joints or failure of caulking, which could lead to:
  • precipitation or meltwater ingress, which could lead to deterioration, which could lead to the structural failure of exterior walls or elements protected by exterior walls, or
  • falling cladding components.
This is to limit the probability of harm to persons.