Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.28.1.1.(1) | Application | Intent |
OH1 | OS2 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Substrate for stucco applied over wood-frame walls,
on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions:
except as stated in Sentence 9.28.4.2.(1), which applies where
not less than 1.19 mm diam galvanized wire is applied horizontally
to the framing at vertical intervals of not more than 150 mm,
or where paper-backed welded wire metal lath is used.
|
Top of Page | |
Intent | Intent 1: To limit the probability of inadequate backing support,
which could lead to inadequate strength to resist impact or other lateral
loads, which could lead to the excessive deformation or cracking of stucco,
which could lead to:
This is to limit the probability of:
This is to limit the probability of:
This is to limit the probability of harm to persons.
|
Top of Page |