Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.28.1.4.(1) | Application | Intent |
OH1 | OS2 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Minimum clearance between finished ground level and
stucco applied over any substrate, on buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
Exceptions:
except for stucco applied over concrete or masonry.
|
Top of Page | |
Intent | Intent 1: To limit the probability of water splashing back from the
ground and penetrating stucco, which could lead to precipitation or meltwater
ingress into the sheathing and framing, which could lead to deterioration,
which could lead to the structural failure of exterior walls or elements protected
by exterior walls, which could lead to harm to persons. |
Top of Page |