Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.28.4.1.(2)
OH1OS2OS1OS3OP1
ObjectiveOP1 Fire Protection of the Building
Attribution
[F80-OP1.1] Applies where stucco is applied to masonry chimneys.
Application
Application 1: 
Corrosion resistance of woven or welded wire mesh supporting stucco, on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of excessive corrosion, which could lead to inadequate support for stucco or swelling of woven or welded wire mesh, which could lead to delamination, disintegration or cracking under gravity, wind or impact loads, or freeze-thaw stresses.
Where stucco is applied to masonry chimneys, this is to limit the probability of precipitation or meltwater ingress, which could lead to the premature failure of chimney liners, which could lead to the escape of heat or flames, which could lead to the ignition of combustible building components, which could lead to damage to the building. [See intent for Sentence 9.21.4.6.(1).]