Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.28.4.2.(1) | Application | Intent |
OH1 | OS2 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Stucco applied over not less than 1.19-mm-diam galvanized
wire that is applied horizontally to the framing at vertical intervals of
not more than 150 mm, or over paper-backed welded wire metal
lath, on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]. |
Top of Page | |
Intent | Intent 1: To limit the probability of inadequate backing support,
which could lead to inadequate strength to resist impact or other lateral
loads, which could lead to the deformation or cracking of stucco.
This is to limit the probability of:
This is to limit the probability of:
This is to limit the probability of:
This is to limit the probability of harm to persons.
Intent 2: To exempt constructions from the application of Sentence 9.28.1.1.(1), where adequate backing support is provided by other means.
|