Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.28.4.5.(1)
OH1OS2OS1OS3OP1
ObjectiveOP1 Fire Protection of the Building
Attribution
[F20-OP1.1] Applies where stucco is applied to masonry chimneys.
Application
Application 1: 
Orientation of stucco lath, on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate strength in the prevailing direction of shrinkage, which could lead to the excessive cracking of stucco.
Where stucco is applied to masonry chimneys, this is to limit the probability of precipitation or meltwater ingress, which could lead to the premature failure of chimney liners, which could lead to the escape of heat or flames, which could lead to the ignition of combustible building components, which could lead to damage to the building. [See intent for Sentence 9.21.4.6.(1).]