Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.28.6.5.(1)
OH1OS2OS1OS3OP1
ObjectiveOS1 Fire Safety
Attribution
[F80-OS1.1] Applies where stucco is applied to masonry chimneys.
Application
Application 1: 
Dampening of the base (second coat) prior to the application of the finish coat of stucco, on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except for stone-dash finish coats.
Top of Page
Intent
Intent 1: 
To limit the probability that the base coat will extract and absorb water from a relatively thin finish coat of stucco, which could lead to negative effects on curing of the finish coat, which could lead to an inadequate resistance to abrasion or freeze-thaw stresses, which could lead to delamination.
Where stucco is applied to masonry chimneys, this is to limit the probability of precipitation or meltwater ingress, which could lead to the premature failure of chimney liners, which could lead to the escape of heat or flames, which could lead to the ignition of combustible building components, which could lead to harm to persons.
Top of Page