Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.29.5.5.(1)
OS2OS1OH1OP2
ObjectiveOS1 Fire Safety
Attribution
[F20-OS1.2] Applies where interior finishes are required to act as fire protection for foamed plastics or to contribute to the required fire resistance of assemblies.
Application
Application 1: 
Minimum length of fasteners for nailed and screwed single-layer installations of gypsum board interior wall and ceiling finishes on wood furring or framing, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except for assemblies required to have a fire-resistance rating, where it can be shown, on the basis of fire tests, that lesser depths of nail penetration are adequate for the required rating.
Application 2: 
This also applies to the protection of foamed plastics that form part of a wall or ceiling assembly in combustible construction :
  • in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Clause 9.10.17.10.(1)(a), and
  • in buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3] that are permitted to be of combustible construction, as stated in Clause 3.1.4.2.(1)(a).
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate penetration of fasteners, which could lead to an inability to resist expected impact, gravity or lateral loads.
This is to limit the probability of the deformation or detachment of interior finishes, which could lead to:
  • where interior finishes are required to protect foamed plastics, a loss of fire protection, or
  • where interior finishes are installed to contribute to the required fire resistance of assemblies, a loss of fire resistance.
This is to limit the probability of the growth and spread of fire, which could lead to harm to persons.
Intent 2: 
To exempt assemblies from the application of this Sentence, where fire tests have proven that shorter nails or screws will be adequate for the required fire-resistance rating.