Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.29.9.1.(1)
OS2OS1OH1OP2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Particleboard interior wall and ceiling finishes, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability that the performance of particleboard interior finishes will fall significantly below expectations, which could lead to an inability to resist expected impact, gravity or lateral loads.
This is to limit the probability of the deformation or detachment of interior finishes, which could lead to:
  • where interior finishes contribute to the required bracing or lateral support for studs, the buckling or racking of walls, which could lead to structural failure, or
  • where interior finishes support or provide the substrate for required environmental separation elements, the excessive deformation, displacement or failure of such elements, which could lead to deterioration, which could lead to further compromised structural integrity.
This is to limit the probability of harm to persons.