Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.29.10.2.(2) | Application | Intent |
OS2 | OS1 | OH1 | OP2 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Aggregate/cementitious material ratio for mortar for
ceramic tile interior wall finishes installed on a mortar base, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9]. |
Top of Page | |
Intent | Intent 1: To limit the probability of inadequate strength of cementitious
material, which could lead to the dislodgement of tiles or the ingress of
water behind tiles, which could lead to compromised protection for moisture-vulnerable
substrates, which could lead to the deterioration of the substrate, which
could lead to studs being unable to resist expected impact, gravity or lateral
loads. This is to limit the probability of the deformation
or detachment of interior finishes, which could lead to:
This is to limit the probability of harm to persons.
|