Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.30.2.5.(1)
OS3OS2OH1
ObjectiveOS2 Structural Safety
Attribution
[F81-OS2.3] Applies where finished flooring is required to provide water resistance.
Application
Application 1: 
Patching of defects in underlay to be installed beneath resilient or ceramic floors applied with an adhesive, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability that finished flooring will collapse into open defects in the underlay, which could lead to the displacement or cracking of finished flooring.
Where finished flooring is required to provide water resistance, this is to limit the probability of the ingress of water into the subfloor, which could lead to compromised structural integrity of the supporting structure, which could lead to an inability to resist expected gravity loads, which could lead to structural collapse, which could lead to harm to persons.