Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.32.3.8.(4)
OS3OH1
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Introduction and minimum temperature of outdoor makeup air for any mechanical air-exhausting device, in dwelling units that:
This applies to self-contained mechanical ventilation systems serving single dwelling units with 5 or fewer bedrooms that are supplied with electrical power and a heating system, in buildings to which:
  • Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], or
  • Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 6 and Sentence 6.2.2.1.(3)].
Exceptions: 
except as stated in:
  • Sentence 9.32.3.8.(2), which exempts the principal ventilation fan operating at a rate not greater than the maximum permitted in Table 9.32.3.3. from the requirements in Article 9.32.3.8. that address the supply of outdoor makeup air to mechanical air exhausting devices,
  • Sentence 9.32.3.8.(8), which exempts dwelling units with solid-fuel-burning appliances from the requirement for outdoor makeup air when all other fuel-fired appliances are direct-vented or mechanically vented and soil gas is not a concern,
  • Sentence 9.32.3.8.(9), which exempts dwelling units from the requirements for outdoor makeup air in Article 9.32.3.8. where a test performed in accordance with the procedures in CAN/CGSB-51.71 indicates that the maximum depressurization levels will not exceed acceptable limits, and
  • Sentence 9.32.3.1.(1), which applies to heating-season mechanical ventilation systems designed to comply with CAN/CSA-F326-M.
Top of Page
Intent
Intent 1: 
To limit the probability that occupants will disable outdoor air supply fans, which could lead to excessive negative pressure, which could lead to the spillage of carbon monoxide gas from fuel-burning appliances that are susceptible to spillage, which could lead to the acute poisoning or asphyxiation of persons.
Intent 2: 
To exempt mechanical air exhausting devices that are principal ventilation fans operating at a rate not greater than the maximum permitted in Table 9.32.3.3. from the provisions in Article 9.32.3.8. for outdoor make-up air fans, on the basis that Articles 9.32.3.4. and 9.32.3.5. address outdoor make-up air for the principal ventilation fan.