Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.32.3.12.(3) | Application | Intent |
OH1 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Connection of two or more heat recovery ventilators
to a common downstream exhaust duct, in self-contained
heating-season mechanical ventilation systems serving single dwelling
units with 5 or fewer bedrooms that are supplied with electrical power
and a heating system, in buildings to which:
Exceptions:
except as stated in Sentence 9.32.3.1.(1), which applies to
heating-season mechanical ventilation systems designed to comply with CAN/CSA-F326-M.
|
Top of Page | |
Intent | Intent 1: To limit the probability of the exhaust side of a heat recovery
ventilator drawing air through another non-operating heat recovery ventilator,
which could lead to a reduced volume of air being exhausted through the intended
exhaust duct. This is to limit the probability of inadequate
ventilation, which could lead to the inadequate control of:
This is to limit the probability of negative effects on the air
quality of indoor spaces, which could lead to harm to persons.
|