Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.32.3.13.(8)
OH1OS1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Exhaust outlets, in self-contained heating-season mechanical ventilation systems serving single dwelling units with 5 or fewer bedrooms that are supplied with electrical power and a heating system, in buildings to which:
  • Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], or
  • Part 6 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 6 and Sentence 6.2.2.1.(3)].
Exceptions: 
except:
  • for exhaust outlets that serve heat recovery ventilators, and
  • as stated in Sentence 9.32.3.1.(1), which applies to heating-season mechanical ventilation systems designed to comply with CAN/CSA-F326-M.
Top of Page
Intent
Intent 1: 
To limit the probability of the entry of vermin (such as mice, rats or squirrels) into buildings, which could lead to damage to electrical wiring, which could lead to the ignition of combustible materials, which could lead to harm to persons.
Intent 2: 
To exempt exhaust outlets serving heat recovery ventilators from the requirement to install backdraft dampers, on the basis that the internal resistance of the heat recovery ventilator core provides sufficient resistance to backdraft.