Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.33.6.2.(4) | Application | Intent |
OS1 | OP1 |
Objective | OP1 Fire Protection of the Building |
Attribution | |
Application | Application 1: Duct connectors that contain combustible materials
and that are used between ducts and air outlet units, in air duct distribution
systems serving heating systems in which the rated heat input does not exceed 120
kW and serving only one dwelling unit,
in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]. Application 2: This also applies to ventilation ducts and their fittings,
as stated in Sentence 9.32.3.11.(1). |
Top of Page | |
Intent | Intent 1: To exempt duct connectors from the application of Sentence 9.33.6.2.(1), where certain criteria are met. This
is to limit the probability of the ignition of combustible duct system components,
which could lead to the spread of fire and smoke throughout the building,
which could lead to damage to the building.
|