Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.33.6.6.(2)
OS1OS3OH1OS2
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Material for duct supports, in air duct distribution systems serving heating systems in which the rated heat input does not exceed 120 kW and serving only one dwelling unit, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Application 2: 
This also applies to ventilation ducts and their fittings, as stated in Sentence 9.32.3.11.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that inadequate support will lead to the collapse of ducts, which could lead to falling parts, which could lead to harm to persons. [See Sentence 9.33.6.7.(3) for the requirement regarding the support of branch ducts.]