Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.33.6.7.(2) | Application | Intent |
OH1 | OS2 | OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Fastening of trunk supply ducts,
in air duct distribution systems serving heating systems in which the rated
heat input does not exceed 120 kW and serving only one dwelling unit, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9]. Application 2: This also applies to ventilation ducts and their fittings,
as stated in Sentence 9.32.3.11.(1). |
Top of Page | |
Intent | Intent 1: To limit the probability of sheet metal failure at nail
heads, which could lead to the collapse or opening of joints and air leakage
at duct connections, which could lead to combustible elements being exposed
to heat radiated from a furnace heat exchanger, which could lead to fire,
which could lead to harm to persons. |