Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.33.6.7.(3)
OH1OS2OS3
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Support for branch ducts, in air duct distribution systems serving heating systems in which the rated heat input does not exceed 120 kW and serving only one dwelling unit, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Application 2: 
This also applies to ventilation ducts and their fittings, as stated in Sentence 9.32.3.11.(1).
Top of Page
Intent
Intent 1: 
To limit the probability of excessive sagging and misalignment or opening of joints, which could lead to excessive air leakage, which could lead to:
  • an inability to maintain the minimum indoor air temperatures [see Sentence 9.33.3.1.(1)], which could lead to condensation, or
  • inadequate ventilation.
This is to limit the probability of:
  • the inadequate control of airborne pollutants or relative humidity, or
  • inadequate combustion air for fuel-burning appliances, which could lead to incomplete combustion.
This is to limit the probability of:
  • the generation of pollutants from biological growth or from materials that become unstable on wetting,
  • the deterioration of building elements, or
  • the entry of combustion products into living space.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces, or
  • the inadequate thermal comfort of persons.
This is to limit the probability of harm to persons.
Top of Page