Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.33.6.13.(1) | Application | Intent |
OH1 | OS3 |
Objective | OH1 Indoor Conditions |
Attribution | |
Application | Application 1: Placement of return-air inlets, in air duct distribution
systems serving heating systems in which the rated heat input does not exceed 120
kW and serving only one dwelling unit,
in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]. |
Top of Page | |
Intent | Intent 1: To limit the probability of an inadequate supply of make-up
air, which could lead to negative pressure in a fire chamber, which could
lead to the flow of combustion products into the air distribution system,
which could lead to negative effects on the air quality of indoor spaces,
which could lead to harm to persons. |