Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.33.6.14.(6)
OH1OS2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Maximum number of openings in vertical return ducts, in air duct distribution systems serving heating systems in which the rated heat input does not exceed 120 kW and serving only one dwelling unit, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of connecting return ducts to rooms on multiple floor levels with different stack pressures, which could lead to an inadequate flow of return air from upper-level rooms, which could lead to an inability to regulate the flow of warm air to rooms, which could lead to an inability to maintain the minimum indoor air temperatures [see Sentence 9.33.3.1.(1)], which could lead to condensation, which could lead to deterioration, which could lead to compromised structural integrity, which could lead to harm to persons.