Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.33.7.1.(1) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Noncombustible lining
or backing for steam or hot water radiators and convectors in which the rated
heat input does not exceed 120 kW and that are located in recesses
or concealed spaces or attached to the face of walls of combustible
construction, serving only one dwelling unit,
in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]. |
Top of Page | |
Intent | Intent 1: To limit the probability of the long-term exposure of combustible
materials to relatively low-grade heat, which could lead to the ignition of
the combustible materials, which could lead to harm to persons.
|