Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.33.9.1.(1)
OH1
ObjectiveOH1 Indoor Conditions
Attribution
(a),(b),(c) [F43-OH1.1] [F51-OH1.2]
Application
Application 1: 
Installation of cooling units combined with fuel-fired furnaces sharing a duct system, in heating and air-conditioning systems serving only one dwelling unit, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of the inappropriate placement of cooling system evaporator coils, which could lead to overheating of the evaporator coil, which could lead to an increase in pressure, which could lead to:
  • the rupture of the coil and loss of refrigerant gases, or
  • the inadequate operation of cooling systems.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces, or
  • the inadequate thermal comfort of persons.
This is to limit the probability of harm to persons.