Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.35.3.2.(2)
OS2OH1OP2OH4OS3
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Construction joints for carports or garages attached to dwelling units directly or by a breezeway, serving not more than one dwelling unit, for buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where both the main building and the garage or carport are supported by slab-on-ground construction.
Top of Page
Intent
Intent 1: 
To limit the probability that frost-related soil movement beneath the adjacent slabs-on-ground will be transmitted, which could lead to excessive stresses, which could lead to the cracking of slabs-on-ground supporting attached buildings, which could lead to an inability to support vertical building loads.
This is to limit the probability of:
  • structural failure, or
  • compromised structural integrity of elements supported by the slab, which could lead to the failure of environmental separation elements, which could lead to the deterioration of building elements.
This is to limit the probability of harm to persons.
Top of Page