Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.33.4.7.(1)
OH1OS3
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Heating and air-conditioning systems serving garages that are part of a single dwelling unit, and systems serving other occupied parts of a single dwelling unit but located in or running through a garage, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability that contaminants that may be present in the garage will migrate from the garage into the dwelling unit, which could lead to the accumulation of such contaminants to levels that could pose a risk to human health from long-term exposure, which could lead to harm to persons.
Top of Page