This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.9.16.(5) | Application | Intent |
OS3 | OS1 |
Objective | OS3 Safety in Use |
Attribution | |
Application | Application 1: Membrane materials used in the air
barrier system required in Sentence 9.10.9.16.(4) between a storage garage and the remainder of the building,
where the storage garage is attached to or built
into a building of residential
occupancy. This applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
|
Top of Page | |
Intent | Intent 1: To limit the probability of premature failure and loss of
airtightness of the air barrier system, which could lead to the migration
of gas and fumes from the garage into the remainder of the building, which
could lead to the accumulation of gas and fumes to levels that pose a risk
to human health from short-term exposure, which could lead to harm to persons.
|
Top of Page |