Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

4.1.3.2.(2)
OS2OS2OP2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Load combinations to be used in the structural design of buildings for strength and stability using the limit states method.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are required to be designed in accordance with the requirements of Part 4.
Top of Page
Intent
Intent 1: 
To limit the probability that the load combinations used for the structural design will not take into account the maximum expected loads as they occur in their expected combinations, which could lead to structural failure, which could lead to harm to persons.
Top of Page