Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
4.1.3.2.(3) | Application | Intent |
OS2 | OP2 |
Objective | OP2 Structural Sufficiency of the Building |
Attribution | |
Application | Application 1: Load factors and effects due to earth pressure, [H],
pre-stress, [P], and dimensional changes and differential settlement, [T],
to be considered in the design of buildings and
their structural components.
|
Top of Page | |
Intent | Intent 1: To limit the probability that the effects of contraction
or expansion caused by temperature changes, shrinkage, moisture changes, creep
in component materials, movement due to differential settlement, and lateral
earth pressure as well as the effects of pre-stress will not be taken into
account in the structural design, which could lead to structural failure,
which could lead to damage to the building. |
Top of Page |