Warning This information has been archived because it is outdated and no longer relevant.

Archived Content

Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

4.1.3.2.(7)
OS2OP2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Load factor for the dead load for soil, superimposed earth, plants and trees on buildings.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are required to be designed in accordance with the requirements of Part 4.
Top of Page
Intent
Intent 1: 
To limit the probability that dead load due to soil, superimposed earth, plants and trees will not be taken into account in the structural design, with respect to how these loads impact on the total load, which could lead to structural failure, which could lead to harm to persons.
Intent 2: 
To allow a reduction in the dead load factor for soil, superimposed earth, plants and trees, where the depth of the soil is greater than 1.2 m, on the basis that a slight variation in the depth will not have as big an impact on the total load.
Top of Page