Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
4.1.5.1.(1) | Application | Intent |
OS2 | OP2 | OH4 |
Objective | OH4 Vibration and Deflection Limitation |
Attribution | |
Application | Application 1: Determination of live loads due
to use and occupancy on floors and roofs as specified
in Sentences 4.1.5.3.(1) and 4.1.5.10.(1) for
the structural design of buildings.
|
Top of Page | |
Intent | Intent 1: To limit the probability that the live load due to use and
occupancy, which is used for the design of structural elements, will not take
into account the most critical of the uniformly distributed specified live
load, the live load resulting from the intended use or the concentrated specified
live load, which could lead to the excessive deflection or excessive vibration
of structural elements, which could lead to negative effects on the psychological
well-being of persons. Intent 2: To direct Code users to Sentence 4.1.5.3.(1) for specified
uniformly distributed live load due to use and occupancy, and to Sentence 4.1.5.10.(1) for
specified concentrated live load due to use and occupancy. Intent 3: To direct Code users to Sentence 4.1.5.1.(2) for buildings
in the Low Importance Category according to Table 4.1.2.1.
|
Top of Page |