Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

4.1.7.3.(1)
OS2OP2OH4
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Distribution of wind loads acting over surface areas of buildings and along each of the two principal horizontal axes of buildings.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are required to be designed in accordance with the requirements of Part 4.
Top of Page
Intent
Intent 1: 
To limit the probability that:
  • the distribution of wind load over surface areas of a building will not take into account the expected distribution of maximum wind pressures on the surface areas, including probable uniform as well as non-uniform distribution due to wind turbulence and wind direction, and
  • the distribution of wind load along the two principal horizontal axes of a building will not take into account the effects of expected maximum winds from all directions.
This is to limit the probability that the high forces in critical structural elements (e.g. structural columns sensitive to building torsion, web diagonals of roof trusses) will be undervalued in the calculations, which could lead to structural failure, which could lead to harm to persons.
Top of Page