Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

4.1.8.11.(10)
OS2OP2OS2OP2
ObjectiveOP2 Structural Sufficiency of the Building
Attribution
(b) [F20-OP2.1] [F22-OP2.4]
Application
Application 1: 
Determination of seismic torsional effects for structures that are torsionally flexible, where IEFaSa(0.2) is equal to or greater than 0.35.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are required to be designed in accordance with the requirements of Part 4.
Top of Page
Intent
Intent 1: 
To limit the probability that the calculation of loads due to earthquake will not take into account the forces due to the expected seismic torsional moment at any level of the building, taking into account the dynamic response of the building to maximum expected seismic ground motions, which could lead to:
  • the excessive deformation of, or excessive stress in, the structural elements, which could lead to damage to the building, or
  • the excessive deformation of, or excessive stress in, the building structure, which could lead to damage to the building, which could impede the intended use and occupancy of the building.
Intent 2: 
To direct Code users to Article 4.1.8.12. for the Dynamic Analysis Procedure.